We appreciate your interest in Electric Boat Corporation part number H677-2201-198, which is currently ready for procurement here on Prompt Aerospace. For your reference, part number H677-2201-198 is listed with the NSN 5925-01-497-1061 and description “Circuitbreaker.” If this is the item you are seeking and you would like to request a quote for your comparisons, simply complete the form below with information like your desired quantity, budget, and anticipated fulfillment timeframe. We regularly respond to requests within 15 minutes of receiving them, using the details we are offered to curate the most ideal purchasing options.
Note : We Will Not Share Your Information To Any Third Parties.
If you want to explore other items produced by Electric Boat Corporation under the CAGE Code 96169 or that similarly fall under the FSC 5925 Circuit Breakers, keep in mind that since we list everything with relevant information, you can easily locate related part numbers using our search engine or catalogs. We also excel at tracking down parts with long lead times or that are generally hard to find, meaning that we can serve you even if you do not see exactly what you need on our website. With all of this being said, we are ready to help you source any of the NSN 5925-01-497-1061 parts and Circuitbreaker items your operations require, so request a quote today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-497-1061 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014971061 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MIL-PRF-39019/4 | 5 | 1 | 4 |
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 800.0 ALL LOCATIONS |
SR-1 | SPEC/STD CONTROLLING DATA | |
CPRQ | RESET METHOD | MANUAL |
THSD | THREAD SERIES DESIGNATOR | UNEF |
AKPX | POLE QUANTITY | 2 |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 23.0 DEG CELSIUS MINIMUM AND 27.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC ALL LOCATIONS |
CMLP | THREAD QUANTITY PER INCH | 32 |
ADTV | CASE MATERIAL | METAL |
ADAT | BODY WIDTH | 1.281 INCHES MAXIMUM |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC ALL LOCATIONS |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AGAV | III END ITEM IDENTIFICATION | WEAPON LAUNCH CONSOL ASSEMBLY FOR LOS ANGELES CLASS SUBMARINE 688 |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.625 INCHES NOMINAL |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
ABXD | BUSHING LENGTH | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | DOUBLE POLE, SINGLE THROW, NORMALLY CLOSED |
FREQ | FREQUENCY IN HERTZ | 60.0 OR 400.0 ALL LOCATIONS |
SR-1 | MANUFACTURERS CODE | 81349 |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
TTQY | TERMINAL TYPE AND QUANTITY | 4 SCREW |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.240 MAXIMUM AT 400 PCT AND 0.060 MAXIMUM AT 800 PCT ALL LOCATIONS |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39019/04-215S |
CPRX | ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC ALL LOCATIONS |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-39019/4 GOVERNMENT SPECIFICATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND FUNGUS RESISTANT AND HERMETICALLY SEALED |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.950 INCHES MAXIMUM |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39014/4 |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.906 INCHES MAXIMUM |