We appreciate your interest in General Electric Company part number 5K254BC204RWB, which is currently ready for procurement here on Prompt Aerospace. For your reference, part number 5K254BC204RWB is listed with the NSN 6105-01-380-2144 and description “Motor Alternating Current.” If this is the item you are seeking and you would like to request a quote for your comparisons, simply complete the form below with information like your desired quantity, budget, and anticipated fulfillment timeframe. We regularly respond to requests within 15 minutes of receiving them, using the details we are offered to curate the most ideal purchasing options.
Note : We Will Not Share Your Information To Any Third Parties.
If you want to explore other items produced by General Electric Company under the CAGE Code 02989 or that similarly fall under the FSC 6105 Motors Electrical, keep in mind that since we list everything with relevant information, you can easily locate related part numbers using our search engine or catalogs. We also excel at tracking down parts with long lead times or that are generally hard to find, meaning that we can serve you even if you do not see exactly what you need on our website. With all of this being said, we are ready to help you source any of the NSN 6105-01-380-2144 parts and Motor Alternating Current items your operations require, so request a quote today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6105-01-380-2144 Item PartTypeName: MOTOR,ALTERNATING CURRENT | 6105 | 013802144 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5K254BC204RWB | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAJV | OVERALL WIDTH | 12.500 INCHES |
AKPS | DUTY CYCLE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CNMM | FRAME SIZE DESIGNATION | 254T |
CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.250 INCHES |
CWDY | TEMP RATING | 50.0 AMBIENT DEG CELSIUS |
CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.000 INCHES |
CWGD | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 6.250 INCHES |
FREQ | FREQUENCY IN HERTZ | 50.0 INPUT OR 60.0 INPUT |
CWDM | SHAFT CENTER TO MOUNTING SURFACE DISTANCE | 6.250 INCHES FIRST END |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 575.0 LINE TO NEUTRAL SINGLE INPUT |
AAJT | OVERALL HEIGHT | 12.500 INCHES |
AXGY | MOUNTING METHOD | FIXED BASE |
BFMF | COOLING METHOD | FAN COOLED |
CNXS | POWER RATING | 15.000 HORSEPOWER OUTPUT |
CWCS | LENGTH OF SHAFT FROM HOUSING | 3.900 INCHES SINGLE END |
CWFQ | MOUNTING FACILITY CIRCLE DIAMETER | 12.500 INCHES |
FAAZ | PHASE | THREE INPUT |
AAJU | OVERALL LENGTH | 23.040 INCHES |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
BKPB | CURRENT RATING METHOD | LOAD |
BKPQ | INCLOSURE SPECIFICATION | NEMA |
CWFX | ROTOR SPEED RATING IN RPM | 1500.0 FIRST MULTIPLE NO LOAD OR 1800.0 SECOND MULTIPLE NO LOAD |
CWGL | CURRENT RATING IN AMPS | 14.400 SINGLE INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote