We appreciate your interest in Hydro Aire Inc part number 19417, which is currently ready for procurement here on Prompt Aerospace. For your reference, part number 19417 is listed with the NSN 4320-00-033-4955 and description “Pump Unit Rotary.” If this is the item you are seeking and you would like to request a quote for your comparisons, simply complete the form below with information like your desired quantity, budget, and anticipated fulfillment timeframe. We regularly respond to requests within 15 minutes of receiving them, using the details we are offered to curate the most ideal purchasing options.
Note : We Will Not Share Your Information To Any Third Parties.
If you want to explore other items produced by Hydro Aire Inc under the CAGE Code 81982 or that similarly fall under the FSC 4320 Power And Hand Pumps, keep in mind that since we list everything with relevant information, you can easily locate related part numbers using our search engine or catalogs. We also excel at tracking down parts with long lead times or that are generally hard to find, meaning that we can serve you even if you do not see exactly what you need on our website. With all of this being said, we are ready to help you source any of the NSN 4320-00-033-4955 parts and Pump Unit Rotary items your operations require, so request a quote today.
MRC | Criteria | Characteristic |
---|---|---|
ASWT | Intake Connection Thread Size And Series/Type Designator | 0.562-18 UNF |
AHZA | Pumping Element Operating Position | HORIZONTAL |
AAYV | Discharge Connection Quantity | 1 |
AHYZ | Operating Speed At Rated Capacity | 8000.0 REVOLUTIONS PER MINUTE |
AHYV | Maximum Discharge Flow Rate | 0.5 GALLONS PER MINUTE |
AHYW | Discharge Pressure | 1000.0 POUNDS PER SQUARE INCH GAGE |
ACKL | Media For Which Designed | HYDROCARBON FUELS AND OILS |
AAXS | Prime Mover Cooling Medium | AIR |
AHZR | Rotary Pump Design | GEAR |
ELEC | Voltage In Volts | 26 |
AHZS | Operation Relationship Design | SIMULTANEOUS |
AAXH | Prime Mover Quantity | 1 |
MRC | Decoded Requirement | Clear Text Reply |
ACDC | Current Type | DC |
CSYL | Prime Mover Power Rating | 0.437 HORSEPOWER |
AENC | Pump Quantity | 1 |
AMPS | Current Rating In Amps | 1.5 |
AAYW | Discharge Connection Type | THREADED INTERNAL |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
AAYT | Intake Connection Quantity | 1 |
ASAZ | Discharge Connection Thread Size And Series/Type Designator | 0.437-20 UNF |
AAYU | Intake Connection Type | THREADED INTERNAL |
AKNA | Inclosure Type | FULLY INCLOSED |
ADZC | Environmental Protection | DUST-IGNITION PROOF |