We appreciate your interest in Janco Corporation part number 1962, which is currently ready for procurement here on Prompt Aerospace. For your reference, part number 1962 is listed with the NSN 5930-00-854-2529 and description “Switch Rotary.” If this is the item you are seeking and you would like to request a quote for your comparisons, simply complete the form below with information like your desired quantity, budget, and anticipated fulfillment timeframe. We regularly respond to requests within 15 minutes of receiving them, using the details we are offered to curate the most ideal purchasing options.
Note : We Will Not Share Your Information To Any Third Parties.
If you want to explore other items produced by Janco Corporation under the CAGE Code 91812 or that similarly fall under the FSC 5930 Switches, keep in mind that since we list everything with relevant information, you can easily locate related part numbers using our search engine or catalogs. We also excel at tracking down parts with long lead times or that are generally hard to find, meaning that we can serve you even if you do not see exactly what you need on our website. With all of this being said, we are ready to help you source any of the NSN 5930-00-854-2529 parts and Switch Rotary items your operations require, so request a quote today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-854-2529 Item PartTypeName: SWITCH,ROTARY | 5930 | 008542529 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
P1962 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AASA | THREAD LENGTH | 0.440 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND EXPLOSION PROOF |
ABNB | FIRST FLAT LENGTH | 0.468 INCHES NOMINAL SINGLE ACTUATOR |
ABXF | SHAFT LENGTH | 1.115 INCHES NOMINAL SINGLE ACTUATOR |
AKPY | THROW QUANTITY | 5 EACH SECTION FRONT |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL |
CRSJ | SHAFT TYPE | ROUND,FLATTED SINGLE ACTUATOR |
CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
CSHW | CONTACT SWITCHING ACTION | MAKES BEFORE BREAKS 2ND SECTION FRONT |
CSHW | CONTACT SWITCHING ACTION | MAKES BEFORE BREAKS 3RD SECTION FRONT |
CSHW | CONTACT SWITCHING ACTION | MAKES BEFORE BREAKS 4TH SECTION FRONT |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 36.0 DEGREES SINGLE ACTUATOR |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
ABNC | FLAT HEIGHT | 0.210 INCHES NOMINAL SINGLE ACTUATOR |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
AFBH | INDIVIDUAL SECTION QUANTITY | 7 |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
AKPX | POLE QUANTITY | 1 EACH SECTION FRONT |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES SINGLE MOUNTING FACILITY |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 5 SINGLE ACTUATOR |
CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 6TH SECTION FRONT |
CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 7TH SECTION FRONT |
CSHW | CONTACT SWITCHING ACTION | MAKES BEFORE BREAKS 1ST SECTION FRONT |
CSHW | CONTACT SWITCHING ACTION | MAKES BEFORE BREAKS 5TH SECTION FRONT |
FEAT | SPECIAL FEATURES | FUNGUS PROOF |
THSD | THREAD SERIES DESIGNATOR | UNEF SINGLE MOUNTING FACILITY |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote