We appreciate your interest in Warner Robins Air Logistics Center part number PD07WRGBZOENF10-TYPE2E, which is currently ready for procurement here on Prompt Aerospace. For your reference, part number PD07WRGBZOENF10-TYPE2E is listed with the NSN 4920-01-559-7446 and description “Test Stand Hydrauli.” If this is the item you are seeking and you would like to request a quote for your comparisons, simply complete the form below with information like your desired quantity, budget, and anticipated fulfillment timeframe. We regularly respond to requests within 15 minutes of receiving them, using the details we are offered to curate the most ideal purchasing options.
Note : We Will Not Share Your Information To Any Third Parties.
If you want to explore other items produced by Warner Robins Air Logistics Center under the CAGE Code 98752 or that similarly fall under the FSC 4920 Aircraft Maintenance And Repair Shop Specialized Equipment, keep in mind that since we list everything with relevant information, you can easily locate related part numbers using our search engine or catalogs. We also excel at tracking down parts with long lead times or that are generally hard to find, meaning that we can serve you even if you do not see exactly what you need on our website. With all of this being said, we are ready to help you source any of the NSN 4920-01-559-7446 parts and Test Stand Hydrauli items your operations require, so request a quote today.
MRC | Criteria | Characteristic |
---|---|---|
CGYK | ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE | NOT INCLUDED |
CHGQ | FILTERING SYSTEM | INCLUDED |
AAYJ | HYDRAULIC FLUID FLOW RATE | 40.0 GALLONS PER MINUTE |
BGST | PRESSURE RATING | 250.0 POUNDS PER SQUARE INCH MINIMUM AND 5000.0 POUNDS PER SQUARE INCH MAXIMUM |
ACDC | CURRENT TYPE | AC |
ATJK | POWER SOURCE | ELECTRIC MOTOR |
FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 |
SR-5 | MANUFACTURERS CODE | 98752 |
AMQY | INSTALLATION DESIGN | PORTABLE |
AYJM | ACCUMULATOR | NOT INCLUDED |
SR-5 | THE MANUFACTURERS DATA | |
RDAL | III REFERENCE DATA AND LITERATURE | PD07WRGBZOENF10 |
FAAZ | PHASE | THREE |
ELEC | VOLTAGE IN VOLTS | 380.0 AND 416.0 |
SR-5 | DESIGN CONTROL REFERENCE | PD07WRGBZOENF10/TYPE2E |
FCLS | III FUNCTIONAL CLASSIFICATION | AA-9.3 |
FTLD | III FUNCTIONAL DESCRIPTION | TYPE 2 DUAL SYSTEM ELECTRIC MOTOR DRIVEN UNIVERSAL HYDRAULIC TEST STAND USED IN GROUND CHECKING AND MAINTENANCE OF AIRCRAFT HYDRAULIC SYSTEMS |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | UNIVERSAL HYDRAULIC TEST STAND-DUAL SYSTEM,TRAILER MOUNTED |
AGAV | III END ITEM IDENTIFICATION | GENERAL AIRCRAFT |
ALBY | USAGE DESIGN | AIRCRAFT HYDRAULIC SYSTEM |
CGYM | PRESSURE MANIFOLD SUBCIRCUIT | INCLUDED |
CHGN | SUBCIRCUIT QUANTITY AND MAXIMUM OPERATING PRESSURE | TWO 5000PSI |